VESDAnet Card for integration into other devices VESDAnet
The VESDAnet™ Interface Card (VN Card) is a simple interface card for the range of Xtralis VESDA VLF smoke detectors. The VN Card provides seamless VESDAnet communication from the detector to other VESDAnet devices, including configuration and monitoring tools.
VESDAnet is a fault-tolerant proprietary Xtralis VESDA communications protocol. VESDAnet allows the Xtralis VESDA range of smoke detectors, displays, programmers and remote units to communicate with each other on one network.
Installing a VESDAnet Interface Card into a VLF detector and connecting to a VESDAnet offers many benefits, including:
VESDAnet allows sophisticated configuration, monitoring and control from local or remote sites. So rather than a technician having to connect to each Xtralis VESDA smoke detector individually (sometimes installed high above floor level), they can communicate with all detectors on the network from a central, convenient, location using a laptop.
VESDAnet also allows a system management package (such as Xtralis VSM4) to monitor and report on the status of all devices connected on VESDAnet, facilitating central supervision, management and control of all Xtralis VESDA detectors.
By installing a VN Card in a VLF detector, remote displays and remote relays can be added to the VLF. This extends the capability and flexibility of the VLF detector.
Using an appropriate High Level Interface (HLI), the information on VESDAnet can be transmitted to 3rd party monitoring and control systems such as Building Management Systems (BMS) and Fire Alarm Control Panels (FACP).
The VLF can be used as a cost effective reference detector for other active detectors on a VESDAnet. Referencing is a technique used to reduce the risk of unwanted alarms caused by external influences to a building, such as air pollution. It works by offsetting the signal from the active detector in the protected area with a reference signal from a detector monitoring the fresh air intake to the area. This results in the active detector measuring changes in smoke levels that are due only to events in the protected area,
Specifications
Power Consumption Consumes less than 1 W from the detector at 24 VDC & 42 mA.
Dimensions Length x Width x Height 5¼”(137 mm) x 2 13/ 16”(71 mm) x 13/ 16”(20 mm) Weight 0.176 lb (0.08 kg)
Terminals 30-12 AWG (0.2 - 2.5 mm2)
Operating Conditions
Detector Ambient 32 to 104°F (0 to 40°C)
Humidity 5% to 95% (non-condensing)
Product Warranty 2 years
Compatibility
Individual VLF detectors can be interrogated and configured by Xtralis VSC, through their onboard serial interface. However, it is not possible to access other detectors on VESDAnet through this serial port.
To configure devices via VESDAnet, an High Level Interface (HLI) must be connected to a VESDAnet socket. This socket is available on VLP, VLS and VLC-505 detectors.
Alternatively, a remote VESDAnet socket module (VRT-300) provides direct connectivity to an HLI or a hand held programmer.
A hand-held programmer or High Level Interface (HLI) module cannot be directly connected to a VLF detector.
Ordering Information
Product Part number
VESDAnet Interface Card VIC-010
Includes: interface card, interface cable,
screws and VESDAnet cable connectors
VIC-010, Vesda, VESDAnet, Vesda Net Car, suction accessory devices